| |
A Focus
on MR Engineering
Room 4A Thursday 13:30 - 15:30
Time |
Prog # |
Computer# |
|
13:30 |
3542 |
6 |
Digital Wireless
Transmission for MRI
Juan Wei1,
Bing Wu1, Jing Yuan1, Gary X. Shen1
1The
University of Hong Kong, Hong Kong, People’s Republic of China |
13:30 |
3543 |
7 |
RF Coil Interface for
Translational Research on Clinical MR Systems
David Michael
Peterson1, Robert J. Fitzsimmons1, Jeffrey R.
Fitzsimmons1
1University
of Florida, Gainesville, Florida, USA |
13:30 |
3544 |
8 |
Time Constant
Sensitivity of Eddy Current Characterizing Pulse Sequence
Daniel B. Ennis1,
Marcus T. Alley1, Brian A. Hargreaves1, Norbert J.
Pelc1
1Stanford University,
Palo Alto, California, USA |
13:30 |
3545 |
9 |
Registration
Technique of Endoscopic Scintillator on MRI Using Optical Position
Sensor for Early Detection of
Gastrointestinal
Stromal Cancer
Hiroshi Sato1,
Hiroshi Watabe1, Noboru Teramoto1, Kazuhiro
Koshino1, Akihide Yamamoto1, Jun-ichiro Enmi1,
Takao Goto2,
Yuji Iwadate2, Tetsuji Tsukamoto2, Hidehiro Iida1
1National
Cardiovascular Center Research Institute, Suita, Osaka, Japan; 2GE
Yokogawa Medical Systems, Hino, Tokyo, Japan |
14:00 |
3546 |
9 |
Feasibility and
Challenges of Dual-Modality Pinhole SPECT / MRI Systems
James William
Kristian Odegaard1, Parisa Jamali1, Hao Peng1,
William Bradfield Handler1, Timothy J. Scholl1,
Blaine
Alexander Chronik1
1University
of Western Ontario, London, Ontario, Canada |
14:00 |
3547 |
8 |
Structural-Acoustic
Analysis, Identification and Control of a 4T MRI Scanner
Mingfeng Li1,
Teik C. Lim1, Christy K. Holland1, Suzanne E.
Boyce1, Jing-Huei Lee1
1University
of Cincinnati, Cincinnati, Ohio, USA |
14:00 |
3548 |
7 |
The Accuracy of
Transmitter Gain Optimization at 7T
Douglas A C
Kelley1
1GE
Healthcare, San Francisco, California, USA |
14:00 |
3549 |
6 |
A Helmet Coil with
Reduced Out-Of-Volume Sensitivity for Human Brain Imaging at 7 T
Wolfgang
Driesel1, Christopher John Wiggins2, Graham
Charles Wiggins2, Lawrence L. Wald2, Toralf
Mildner1, Harald E.
Möller1,
3
1Max
Planck Institute for Human Cognitive and Brain Sciences, Leipzig,
Germany; 2Massachusetts General Hospital, Charlestown,
Massachusetts, USA; 3University Hospital Münster, Münster,
Germany |
14:30 |
3550 |
6 |
Comparison of Four
Different Birdcage Type Coils
Wanzhan Liu1,
Christopher M. Collins2, Michael B. Smith2
1University
of Minnesota, Minneapolis, Minnesota, USA; 2Penn State
College of Medicine, Hershey, Pennsylvania, USA |
14:30 |
3551 |
7 |
Parallel Transmit
with a Single Exciter and a Multi-Channel Controller
Mika W. Vogel1,
Dirk Lange1, Patrick Gross1, Florian Wiesinger1,
Wolfgang Loew1, Hartmut Koenig1, Rolf Schulte1,
Ronald D.
Watkins2
1GE
Global Research, Munich, Bayern, Germany; 2GE Global
Research, Niskayuna, New York, USA |
14:30 |
3552 |
8 |
Sound Level
Measurements in MR Scanners: A Comparative Study
Krzysztof R.
Gorny1, Diana M. Lanners1, Matthew A. Bernstein1
1Mayo
Clinic, Rochester, Minnesota, USA |
14:30 |
3553 |
9 |
A Novel Quantitative
Method for Measuring the Torque Acting on Cardiovascular Implantable
Devices in NMR
Scanners
Rossella Canese1, Giuseppe D'Avenio1,
Franca Podo1, Mauro Grigioni1
1Istituto
Superiore di Sanità, Rome, Italy |
15:00 |
3554 |
9 |
Clinical Safety of
Magnetic Resonance Imaging on Recently Placed Coronary Artery Stents
Donna S.
Lesniak1, Brian A. Seeck1, Joseph A. Craft1,
George S. Chrysant1, Robert J. Gropler1, Pamela K.
Woodard1
1Washington
University School of Medicine, St. Louis, Missouri, USA |
15:00 |
3555 |
8 |
MR Imaging of Mouse
Heart In Vivo at 4.7T Using the Homebuilt RF Probehead and
Gradient System
Sylwia
Heinze-Paluchowska1, Tomasz Skorka1, Andrzej
Jasinski1, 2, Roman Wiertek1, Piotr
Skora1, Jacek Kiczek1,
Pawel Borowiec1
1H.
Niewodniczanski Institute of Nuclear Physics PAS, Krakow, Poland; 2Department
of Dielectric and Biophysics, Pedagogical University, Krakow, Poland |
15:00 |
3556 |
7 |
Slant-Slice Imaging
with an Inhomogeneous Field
Charles L.
Epstein1, Jeremy F. Magland2
1University
of Pennsylvania, Philadelphia, Pennsylvania, USA; 2Hospital
of the University of PA, Philadelphia, Pennsylvania, USA |
15:00 |
3557 |
6 |
Comparison of a TEM
Head Coil with an 8 Channel Head Array Coil at 3 Tesla
Ralf Mekle1,
2, Rolf Gruetter1, 2
1Ecole
Polytechnique Federale de Lausanne, Lausanne, Switzerland; 2University
of Lausanne, Lausanne, Switzerland |
|