| |
New Developments in
Parallel Imaging RF Array Coil Design
Room 6C
11:00 - 13:00
Chairs: Mary McDougall and Larence L. Wald
Time |
Prog # |
|
11:00 |
415. |
A 32 Channel
Receive-Only Head Coil and Detunable Transmit Birdcage Coil for 7 Tesla
Brain Imaging
Graham Charles Wiggins1,
Christopher John Wiggins1, Andreas Potthast2,
Vijay Alagappan1, Oliver Kraff3,
Arne Reykowski4,
Lawrence L. Wald1
1Massachusetts
General Hospital, Charlestown, Massachusetts, USA; 2Siemens
Medical Solutions, Inc, Malvern, Pennsylvania, USA; 3University
Hospital Essen, Essen, Germany; 4Invivo Corporation,
Gainesville, Florida, USA |
11:12 |
416. |
An Adjustable 8-Channel Coil
Array for MRI of the Human Wrist
Jurek Antonin
Massner1, Nicola De Zanche1, Klaas Paul Pruessmann1
1University and ETH
Zurich, Zurich, Switzerland |
11:24 |
417. |
Experimental and Numerical
Investigations of SENSE Array Performances from High to Ultra-High Field
Strengths
Shumin Wang1,
Patrick J. Ledden2, Jacco A. de Zwart1, Peter van Gelderen1,
Alan Koretsky1, Jeff H. Duyn1
1LFMI,
NINDS, National Institutes of Health, Bethesda, Maryland, USA; 2Nova
Medical, Inc., Wilmington, Massachusetts, USA |
11:36 |
418. |
36 Channel
Peripheral Angio Matrix Coil for 3 Tesla
Volker Matschl1,
Helmut Kess1, Karsten Jahns1, Heinz Hahn1,
Helmut Greim1, Harald Kramer2, Stefan Schoenberg2,
Hubertus
Fischer1
1Siemens
Medical Solutions, Erlangen, Germany; 2University of Munich -
Grosshadern Campus, Munich, Germany |
11:48 |
419. |
An 8 Channel Shoulder Coil
for High Resolusion Imaging
Yoshinori Hamamura1,
Brian Brown1, Kyle Johnson1, Jeff Hathaway1,
Ken Meurer1, Murray Wheeler1
1Invivo,
Pewaukee, Wisconsin, USA |
12:00 |
420. |
An Optimised 16-Element Head
Coil for 7T with Integrated Preamplifiers
Yun-Jeong Yang1,
Nicholas Castrilla1, Cliff Mills1, Verna Fitzsimmons2,
Joseph Murphy-Boesch1
1USA
Instruments, Inc., Aurora, Ohio, USA; 2Kent State University, Kent,
Ohio, USA |
12:12 |
421. |
High-Field Transmission Line
Arrays for Transmit and Receive
Carl J. Snyder1,
Lance DelaBarre1, Can Akgun1, Steen Moeller1,
Gregor Adriany1, Kamil Ugurbil1,
John Thomas Vaughan1
1University of
Minnesota, Minneapolis, Minnesota, USA |
12:24 |
422. |
Twenty-Four Channel
Receive-Only Array for Brain Imaging at 7T
Patrick J.
Ledden1, Azma Mareyam1, Shumin Wang2, Peter van
Gelderen2, Jeff H. Duyn2
1Nova
Medical, Inc., Wilmington, Massachusetts, USA; 2National Institutes
of Health, Bethesda, Maryland, USA |
12:36 |
423. |
A 28 Channel Bi-Lateral
Breast Array for Accelerated MR Imaging
Randy O. Giaquinto1,
Charles McKenzie2, Daniel K. Sodickson2, Aaron K. Grant2,
Gordon E. Murtagh1,
Robert L. Furman1,
Leo J. Swider1, Christopher J. Hardy1, Charles L. Dumoulin1
1GE
Global Research, Niskayuna, New York, USA; 2Beth Israel Deaconess
Medical Center, Boston, Massachusetts, USA |
12:48 |
424. |
Measuring Practical Coil
Array Performance with Respect to Ultimate Intrinsic SNR: A Tool for Array
Design and
Assessment
Riccardo
Lattanzi1, 2, Aaron K. Grant2, Michael A.
Ohliger1, 2, Daniel K. Sodickson, 12
1Harvard-MIT,
Cambridge, Massachusetts, USA; 2Beth Israel Deaconess Medical Center,
Boston, Massachusetts, USA |
|