| |
Fat-Water Imaging
Room 613 - 614
16:30 - 18:30
Chairs: Arthur F. Gmitro and Scott B. Reeder
Time |
Prog # |
|
16:30 |
624. |
IDEAL Water-Fat
Separation with Simultaneous T2* Estimation
Huanzhou Yu1,
Charles A. McKenzie2, Ann Shimakawa1, Norbert J.
Pelc3, Jean H. Brittain4, Scott B. Reeder5
1GE
Healthcare, Menlo Park, California, USA; 2Beth
Israel-Deaconess Medical Center and Harvard Medical School, Boston,
Massachusetts, USA; 3Stanford University, Stanford,
California, USA; 4GE Healthcare, Madison, Wisconsin, USA;
5University of Wisconsin, Madison, Wisconsin, USA |
16:42 |
625. |
Fast Water and Fat Imaging
Using a Radial GRASE Technique with the IDEAL Algorithm
Zhiqiang LI1,
Scott W. Squire1, Arthur F. Gmitro1, Maria I. Altbach1
1University
of Arizona, Tucson, Arizona, USA |
16:54 |
626. |
On the Application of the
DIXON Method in Balanced SSFP Imaging
Hyeonjin Kim1,
Alexander B. Pinus1, Philip S. Murphy2, R Todd Constable1
1Yale
University School of Medicine, New Haven, Connecticut, USA; 2Global
Clinical Sciences, Pfizer, Sandwich, UK |
17:06 |
627. |
Gradient Reversal Technique
Revisited for Simultaneous Water and Fat Imaging at High Field
Haiying Tang1, Ed X.
Wu2, Richard Kennan1, Haiying Liu1
1Merck
Research Laboratories, Rahway, New Jersey, USA; 2The University of
Hong Kong, Hong Kong SAR, People’s Republic of China |
17:18 |
628. |
A Single Scan Two-Point Dixon
Technique Using Bunched Phase Encoding
Hisamoto Moriguchi1,
Mark A. Griswold1, Jeffrey L. Sunshine1, Jeffrey L. Duerk1
1University Hospitals
of Cleveland / Case Western Reserve University, Cleveland, Ohio, USA |
17:30 |
629. |
Water-Fat Separation at 3T
with IDEAL and 3DPR
Ethan K. Brodsky1,
Scott B. Reeder1, Huanzhou Yu2, Walter F. Block1
1University
of Wisconsin, Madison, Wisconsin, USA; 2GE Healthcare, Menlo Park,
California, USA |
17:42 |
630. |
Regional Iterative Phasor
Extraction (RIPE): Effective Phase Correction for Water-Fat Imaging
Qing-San Xiang1
1University
of British Columbia, Vancouver, BC, Canada |
17:54 |
631. |
Comparison of In and Out of
Phase Imaging and IDEAL Fat-Water Separation for Liver Imaging at 3.0 T
Charles Alexander McKenzie1,
2, Daniel Sacchetti3, Scott Fredericks3, Michael
Schuster3, Martin Smith3,
Huanzhou Yu4, Anja
Brau4, Ann Shimakawa4, Jean H. Brittain4, Scott
B. Reeder5, Ivan Pedrosa, 23, Neil M. Rofsky, 23
1Beth
Israel Deaconess Medical Center, Boston, Massachusetts, USA; 2Radiology,
Harvard Medical School, Boston, Massachusetts, USA; 3Radiology, Beth
Israel Deaconess Medical Center, Boston, Massachusetts, USA; 4Global
Applied Science Laboratory, GE Healthcare, Menlo Park, California, USA; 5University
of Wisconsin Medical School, Madison, Wisconsin, USA |
18:06 |
632. |
Multi-Echo IDEAL Water-Fat
Separation for Rapid Imaging of Cartilage
Garry E. Gold1, Scott
B. Reeder2, Huanzhou Yu3, Jean H. Brittain4,
Brian A. Hargreaves1
1Stanford
University, Stanford, California, USA; 2University of Wisconsin,
Madison, Wisconsin, USA; 3GE Healthcare, Menlo Park, California, USA;
4GE Healthcare, Madison, Wisconsin, USA |
18:18 |
633. |
T2-TIDE-BSSFP Imaging with
Simple and Robust Fat Suppression
Yin-Cheng Kasuga Huang1,
Teng-Yi Huang2, Hsiao-Wen Chung1, 3
1National
Taiwan University, Taipei City, Taiwan; 2National Taiwan University
of Science And Technology, Taipei City, Taiwan; 3Tri-Service General
Hospital and National Defense Medical Center, Taipei City, Taiwan |
|