| |
Spectroscopic Quantitation
Room 4A Monday 14:00 - 16:00
Time |
Prog # |
Computer# |
|
14:00 |
3222 |
29 |
Direct Validation of In Vivo
Localized 13C MRS Measurements of [1-13C] Glycogen
in Rat Brain
Hongxia Lei1, 2, Tianwen
Yue2, Florence Morgenthaler1, Rolf Gruetter1,
2
1EPFL,
Lausanne, Switzerland; 2University of Minnesota, Minneapolis,
Minnesota, USA |
14:00 |
3223 |
30 |
Metabolic Profiling of post Mortem
Multiple Sclerosis Brain Using High Resolution 1H NMR
Spectroscopy
Klaus DG Schmierer1,
Marc E. Denham1, Sebastian Brander1, David H.
Miller1, Tarek A. Yousry1, Harold G. Parkes1
1Institute
of Neurology, UCL, London, England, UK |
14:00 |
3224 |
31 |
Water as an Internal Reference for
Spectroscopic Imaging: Methodology, Application, and Comparison to
Other
Methods
Charles Gasparovic1, 2,
Tao Song3, Deidre J. Devier1, 4, Arvind
Caprihan5, Paul G. Mullins, 1,2, Rex E. Jung1,
2,
Leslie Morrison1
1University
of New Mexico School of Medicine, Albuquerque, New Mexico, USA; 2The
MIND Institute, Albuquerque, New Mexico, USA; 3University of
California San Diego, San Diego, California, USA; 4University
of New Mexico, Albuquerque, New Mexico, USA; 5New Mexico
Resonance, Albuquerque, New Mexico, USA |
14:00 |
3225 |
32 |
Optimization of Echo Time for GABA
Editing Using MEGA-PRESS
Tsuyoshi Matsuda, RT1, Hirohiko
Kimura, MD, PhD2
1GE Yokogawa Medical Systems,
Hino, Tokyo, Japan; 2University of Fukui, Fukui, Japan |
14:30 |
3226 |
32 |
Effects of Cations
and PH on Optimized Assessment of Prostatic Citrate at 3 Tesla
Kagayaki Kuroda1,
2, Takaki Maeda3, 4, Robert V. Mulkern5,
Naoyuki Takei6, Yasushi Kaji7, Kazuro Sugimura
1Graduate
School of Engineering, Tokai University, Hiratsuka, Kanagawa, Japan;
2Institute of Biomedical Research and Innovation, Kobe,
Hyogo, Japan; 3Kobe University School of Medicine, Kobe,
Hyogo, Japan; 4Tenri Hospital, Tenri, Osaka, Japan; 5Children's
Hospital, Harvard Medical School, Boston, Massachusetts, USA; 6GE
Yokogawa Medical Systems, Hino, Tokyo, Japan; 7Graduate
School of Medicine, Kobe University, Kobe, Hyogo, Japan |
14:30 |
3227 |
31 |
Single Voxel MRS
Measurements Are Not Influenced by Swirling Flow in Phantom Solution
Chen Lin1,
Kejal Kantarci1, John D. Port1, Joel P. Felmlee1,
Clifford R. Jack Jr. 1
1Mayo
Clinic, Rochester, Minnesota, USA |
14:30 |
3228 |
30 |
Metabolite Profiles
Obtained with QUEST from HRMAS-NMR Signals of Rat Brains
Hérald Rabeson1,
Florence Fauvelle2, Hélène Ratiney1, Cristina
Cudalbu1, Dirk van Ormondt3,
Danielle
Graveron-Demilly1
1Université
Claude Bernard, Lyon I - CPE, Villeurbanne, France; 2CRSSA/BCM,
La Tronche, France; 3Delft University of Technology, Delft,
Netherland |
14:30 |
3229 |
29 |
Repeated Measures
Performance of Volumetric Whole Brain Echo Planar Spectroscopic Imaging
Jeffry R. Alger1,
Andrew J. Frew1, Raj Pagare1, Ammar Darkazanli2,
Andrew A. Maudsley2
1University
of California, Los Angeles, Los Angeles, California, USA; 2University
of Miami, Miami, Florida, USA |
15:00 |
3230 |
29 |
Fast Analysis of 1H
Magnetic Resonance Spectroscopic Imaging Data: An Artificial Neural
Network Based
Approach
Himanshu Vishwas Bhat1, Balasrinivasa Rao
Sajja2, Sushmita Datta2, Ponnada A. Narayana2
1University
of Houston, Houston, Texas, USA; 2University of Texas Medical
School at Houston, Houston, Texas, USA |
15:00 |
3231 |
30 |
Accuracy of Exchange
Rate Measurement Using CUPS, a Novel Method for Kinetic Analysis
Craig J. Galban1,
Richard G. Spencer2
1National
Institutes of Health, Bethesda, Maryland, USA; 2National
Institutes of Health, Baltimore, Maryland, USA |
15:00 |
3232 |
31 |
Measuring Glutamate
in the Human Brain by MRS: Reproducibility Using Time Domain Fitting at
3 Tesla
Karen E. Davies1,
Eugenia Leitao1, S Singh1, S Mistry1,
Samantha Jefferson1, Shaheen Hamdy1, Stephen Ross
Williams1
1University
of Manchester, Manchester, UK |
15:00 |
3233 |
32 |
Hyperpolarization by
DNP Is Applicable to 13C Isotopomer Analysis
Matthew Merritt1,
Damir Blazina2, Craig Malloy1
1UTSW
Medical Center, Dallas, Texas, USA; 2Oxford Instruments
Molecular Biotools, Ltd., Tubney Woods, UK |
15:30 |
3234 |
32 |
On the Reliability of
13C Metabolic Modeling Using Two-Compartment Neuronal-Glial
Models
Alexander
Shestov1, Kamil Ugurbil1, Pierre-Gilles Henry1
1University
of Minnesota, Minneapolis, Minnesota, USA |
15:30 |
3235 |
31 |
Very Short Echo Time
STEAM Improves Detection of Glutamate at 3-T
Dattesh D.
Shanbhag1, Sarah Andrea Dunham1, Jack Knight-Scott1
1University
of Virginia, Charlottesville, Virginia, USA |
15:30 |
3236 |
30 |
Water as an Internal
Reference for Spectroscopic Imaging: Variability Due to Partial Volume
Estimates
Charles
Gasparovic1, 2, Tao Song3, Deidre J.
Devier1, 4, Jeremy Bockholt2, Arvind
Caprihan5, Paul G. Mullins, 1,2, Stefan
Posse, 26,
Rex E. Jung1, 2, Leslie Morrison1
1University
of New Mexico School of Medicine, Albuquerque, New Mexico, USA; 2The
MIND Institute, Albuquerque, New Mexico, USA; 3University of
California San Diego, San Diego, California, USA; 4University
of New Mexico, Albuquerque, New Mexico, USA; 5New Mexico
Resonance, Albuquerque, New Mexico, USA; 6University of New
Mexico School of Medicine, Albuquerque, New Mexico, USA |
15:30 |
3237 |
29 |
Error Bounds for
Semi-Parametric Estimation in MRS
Helene Ratiney1,
Enrico Capobianco2, Ronald de Beer3, Dirk van
Ormondt3, Danielle Graveron-Demilly1
1Université
Claude Bernard, Lyon I - CPE, Villeurbanne, France; 2University
of Boston, Boston, Massachusetts, USA; 3Delft University of
Technology, Delft, Netherlands |
|